Series 2 : Adjusting Bean Exit Mechanical Switch

  1. Turn machine off and unplug from wall.
  2. Drain pneumatic system of air pressure. 
  3. Remove bean bucket cubby using #2 phillips screwdriver. 
  4. Manually move the bean exit gates to the open position. 
  5. Using a #1 phillips screw driver remove the plate holding the mechanical microswitch to the cooling tray. 
  6. About half way down the metal tab of the microswitch create a small ~20deg bend in the metal.