- Turn machine off and unplug from wall.
- Drain pneumatic system of air pressure.
- Remove bean bucket cubby using #2 phillips screwdriver.
- Manually move the bean exit gates to the open position.
- Using a #1 phillips screw driver remove the plate holding the mechanical microswitch to the cooling tray.
- About half way down the metal tab of the microswitch create a small ~20deg bend in the metal.
- Reverse the steps to reassemble.